JLCB-M-01 Series PV Combiner Box
JLCB-M-01 Series PV Combiner Box
The JLCB-M-01 series PV combiner box, supporting up to 24 inputs, is designed to provide overcurrent and overvoltage protection, enhancing the safety and reliability of inverters operating in solar power systems with a maximum DC input voltage of 1000V.
Engineered in strict compliance with the CGC/GF 037:2014 standard, the combiner box is constructed from cold-rolled steel and offers a high level of protection with a waterproof rating of IP65. Each unit undergoes rigorous testing for temperature rise, impact resistance, and UV protection to ensure durability and long-term performance.
Custom configurations are available upon request to meet specific user requirements.
Technical Data
| Model | 4/1 | 6/1 | 8/1 | 10/1 | 12/1 | 14/1 | 16/1 | 18/1 | 20/1 | 22/1 | 24/1 |
| Electric Parameter | |||||||||||
| Number of Inputs strings | 4 | 6 | 8 | 10 | 12 | 14 | 16 | 18 | 20 | 22 | 24 |
| Output max power | 32kw | 32kw | 125kw | 125kw | 160kw | 225kw | 250kW | 275kW | 300kW | 315kW | 350KW |
| Max.Rated Voltage DC | 1000V | ||||||||||
| Material of Box | Metal | ||||||||||
| Maximum input current for each string | 15A | ||||||||||
| Maximum output switch current | 20A | 20A/32A | 125A | 125A | 160A | 225A | 250A | 275A | 300A | 315A | 350 |
| Number of Outputs strings | 1 | ||||||||||
| Lightening Protection | |||||||||||
| Category of test | Ⅱ grade protection | ||||||||||
| Nominal discharge current | 20kA | ||||||||||
| Maximum discharge current | 40kA | ||||||||||
| Poles of DC surge protector | 3Poles | ||||||||||
| Voltage protection level Up | 3.8kV | ||||||||||
| Maximum continuous operating voltage Uc | 1050V | ||||||||||
| Structure Characteristic | Plug-push module | ||||||||||
| Product system | |||||||||||
| Protection grade | IP65 | ||||||||||
| Solar connector EMC4 | Standard | ||||||||||
| PG gland | Standard | ||||||||||
| DC fuse | Standard | ||||||||||
| DC SPD | Standard | ||||||||||
| DC circuit breaker | Standard | ||||||||||
| Monitoring module | Optional | ||||||||||
| Anti reverse diode | Standard | ||||||||||
| Installation method | Surface mounting type | ||||||||||
| Ambient temperature range | -25°C~+55°C | ||||||||||
| Altitude | 2000m | ||||||||||
| Permissible relative humidity | 0-95% no condensation | ||||||||||
| Number of Inputs strings | Lightening Protection | ||||||||||
Data Download